7 INSTALLATION AND COMMISSIONING PROCEDURE
7.1 Service-Centre Cabinet Testing
With reference to the Works Specification, check that:
The cabinet is free from external physical damage
The correct cards have been supplied and fitted in the correct positions.
The socketed devices are securely fitted (including Heart and Licence card).
The correct configuration is loaded into the CPU Card
The links and address switches are correctly set on each card
All fuses are fitted securely and are of the correct rating
The primary connections to the Lamp Supply Transformer have been set to
the correct voltage
The connections between the Lamp Transformer secondary and the HPU are
correct and are secure
All plugs and sockets are securely mated
All fixings are tight especially those securing cards to side or back panels of
the cabinet.
Power the cabinet on and run the self-test.
Check the IC4 Configuration Id Code by navigating to the web page:
Status and Configuration Controller IC4 Config
and check that the IC4 Configuration Id Code displayed is the same value that
is printed on the first page of the IC4 printout (IC4 Configuration Id Code)
The RS232 handset command 'CIC' can also be used to check the IC4 Id
against the IC4 printout.
Check the IC4 Checksum value by navigating to the web page:
Status and Configuration Controller IC4 Config
and check that the Checksum displayed is the same value that is printed on
the first page of the IC4 printout (Configuration Check Value)
The RS232 handset command 'CRC' can also be used to check the CRC
value against the IC4 printout.
Finally, before the cabinet leaves the Service Centre:
Tighten the screws on the swing-frame
Place the Junction Plan, the IC4 Printout and the Site Logbook into the pocket
inside the door of the controller
Close and lock the controller door with both key and T-bar locks
Re-package the cabinet with the protective packaging.