Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Copyright © Siemens plc 2020. All Rights Reserved. Mobility is a division of Siemens Plc
RJ45 cable for I/O card 2.0m length
RJ45 cable for I/O card 3.0m length
HPU to LSLS 1 Reg Sign Current Sensor Cable Assy
HPU1 to HPU2 Link Cable Assy
PB815 Firmware PHP PROM (Latest issue)
HPU metal bracket (Single – two required to mount HPU)
Heart of the Controller (SD Card)
A.5 Controller Fuses
The following table lists the fuses fitted in the controller. Fuses should only be
replaced with ones of similar rating and type.
Electricity Company Cut-out - Standard ST950ELV
The Max size of this fuse should not exceed 100A (without reference to
Siemens Poole). Maximum prospective short circuit current must not
exceed 16,000A. Rating depends on application but 45A minimum is
recommended up to 20A load
Electricity Company Cut-out - ST950ELV Low Inrush
Max size and Maximum prospective short circuit current as above.
Recommended rating 16A minimum up to 20A ELV load
Master Switch Fuse - Standard ST950ELV
30A HRC cartridge fuse to BS1361 on Master Switch panel
(or 32A HRC cartridge fuse to BS88)
Master Switch Fuse - ST950ELV Low Inrush
16A HRC cartridge fuse to BS1361 on Master Switch panel
Regulatory Signs Fuse
5A SB 250V 5 x 20mm fuse marked ‘Reg Sign’ on the HPU (F1)
Detector Supply Fuse
5A SB 250V 5 x 20mm fuse marked ‘Detector’ on the HPU (F2)
Solar Cell Supply Fuse