Siemens ST950 - Re-Fit the Cabinet to the Stool

Siemens ST950
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Security classification
Unrestricted
Page
95 of 154
Version
7
Status
Issued
Last Editor
manpreet.jeerh
Date
January 2020
Document Name
ST950 ICM Handbook
Document No.
667/HE/45950/000
Cores
Ident
Stud
Nut
CET Bar
Inner Insulation
Ident
(Alternative position)
Incoming Cable
SIDE VIEW
Mounted at CET Lower Fixing Position
Earthing Band
667/2/02348/000
Wormdrive Hose Clip
991/4/01375/028
PLAN VIEW
(Armouring not shown at
front of ring for clarity)
Lower CET
Fixing Position
Higher CET
Fixing Position
55mm
to
65mm
CET Ring
(Earthing Band)
Hose Clip
Figure 50 - Termination of Armoured Cable to CET bar
7.3.10 Re-fit the Cabinet to the Stool
If the controller cabinet was not installed with the mounting stool then it should be
done as follows: