4.5.2 Connector Pinouts
Connectors 5 and 8 are fitted with long latches that are suitable for use with Berg
housings and individual wire connections. The four connectors that may require
user wiring are detailed below:
Table 2 - Double Stacked 10W IDC – Top: Cabinet Signals Bottom: Aux
RS232
Not Used (because +5V on connector 8)
Not Used (because +5V on connector 8)
Signals on/off switch signal input
Signals on/off switch return (0V)
Cabinet Alarm LED Drive + +5V via 150R resistor
Cabinet Alarm LED Drive - MOSFET open drain output
Reset fault log button input signal
Reset fault log button return (0V)
Functions:
Signals on/off switch (3,4) – This input allows an external switch to be used to
control the signals on/off state. If either the internal (on the manual panel) or
external switches are in the ‘on’ position the signals are requested on. (switch
closed = signals on)