Cabinet Alarm LED Drive (5,6) – This output allows an external LED indicator to be
installed to indicate the cabinet alarm state. This output is current limited to 33mA
under short circuit conditions.
Door Switch (7,8) – This input allows an external switch to be used to connect a
cabinet door switch. (switch closed = door closed) If either this input or the standard
manual panel indicate door closed the controller door state will be closed.
Reset fault log button (9,10) – This input allows an external push button to be used
to reset major faults in the fault log in the same manner as RFL=1 would do from
the handset.
Bottom connector – Serial port used to connect an optional GPS unit (used to
maintain the clock).
Table 3 - Double Stacked 10W IDC- Top: Modem Power + Monitors, Bottom:
EFC Modem
Modem +5V DC fused output from MDU/LPU (not battery
backed)
Modem 0V DC output (+5V return)
External supply monitor signal (digital)
External supply monitor signal return (0V)
External supply monitor signal (analog)
External supply monitor signal return (0V)