Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Security classification
Unrestricted
Page
65 of 154
Version
7
Status
Issued
Last Editor
manpreet.jeerh
Date
January 2020
Document Name
ST950 ICM Handbook
Document No.
667/HE/45950/000
Figure 29 Audible Driver Module Connections Single Output type
4.15.2 Monitored Audibles Single Output type
The /002 variant of the Audible Driver Module has an opto-isolated Monitor Output
that is open-circuit when the audible is voltage is less than 5V and short-circuit
when the audible output has a voltage present of more than 5V. This allows
independent monitoring of the voltage on the audible output. The Monitor Output
can be wired directly to an input of the I/O card.
LSLS O/P
LSLS Return
Numbered
signal output
Return
Audible +
Audible -
-
+
Audible +
Audible -
-
+
Audible 1
Audible 8
Audible
Driver
Module(s)
(4 max)
LSLS
I/O Card
INH -
INH +
Common
Normally Open
Output
Input
Mon Ret *
Mon O/P *
* Only on /002 variant of Module
Common
Input