Introduction
Controller SelfTest
===================
Pause output
question
Q: Pause Display
After 4 Lines? [YN]
Primary control
of self test
Primary
Firmware
Identifies the Primary processor
firmware and package issue
PRI:46020 1.0
SEC CPU
Checks that the SEC processor is
running
SEC CPU......Active
Lamp switch
card
identification
Searches for LSLS cards
This example shows two LSLS cards
LSLS Cards...----21
Details LSLS cards found:
Firmware number and version
Hardware number
Hardware Issue
Date of manufacture
If no inventory information is found:
‘No Inventory Data’ is displayed
2 LSLS Cards
VLS 1:32941 7
HW: 667/1/32943/001
ISS 20
DOM 2013/07/11
VLS 2:32941 ISS 7
No Inventory Data
VLS3:-
VLS4:-
VLS5:-
VLS6:-
PHP CPU
Checks to see if the PHP processor is
running.
Will not be running on an ELV controller
PHP CPU......None
Controller
Type Confirmation
Ok, ELV Controller
EFC control of
self test
Waiting for EFC...
EFC started...
EFC in control...
Primary Inventory tests finished
PRI INV done
EFC Inventory tests start here
EFC INV start
Test ID
System
TEST: System
version:
File system
firmware
Identifies the file system firmware and
version
File system
667/TZ/46059/000
Siemens ST950
Controller
Vers: 1.0

Table of Contents