Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Copyright © Siemens plc 2020. All Rights Reserved. Mobility is a division of Siemens Plc
with 32 on the left, just after the text “32:”. The third line shows the status of LSLS
Outputs 1 to 16, starting with 16 on the left, just after the text “16:” and finishes with
LSLS Output 1 on the right. The fourth line is added to clarify the position of the
digits / bits for LSLS Outputs 8 through to 1. In this example, the LSLS Outputs 5
and 32 appear to be ON.
If more than one LSLS Card is fitted:
identifies the test which has failed
outputs on LSLS#1 and LSLS#4
outputs on LSLS#2 and LSLS#5
outputs on LSLS#3 and LSLS#6
The numbers are in hexadecimal notation with each of the eight digits encoding four
LSLS outputs, so the status of the 32 LSLS Output numbered 1-32 (from right to
left) is shown by the eight digits. Each possible combination of the LSLS outputs is
encoded to a value as follows. In the above example, the voltage monitor for LSLS
Output 32 is indicated as faulty, implying that the output switch (or the monitor) is
faulty.