EasyManua.ls Logo

Sigicom INFRA C22 - Page 66

Sigicom INFRA C22
77 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copyright © Sigicom AB 2021
66
55B. ISEE/USBM
Same as standard 51B, ISEE standard, but in SI units.
Level and frequency ranges: 25 mm/s, 2-250 Hz.
Max resolution in presentation: 0.005 mm/s and 3 significant digits.
Threshold range: 0.04 22 mm/s.
57A. DIN 4150-3 Anlage (US-units)
Erschütterungen im Bauwesen Teil 3: Einwirkungen auf bauliche
Anlage.
Level and frequency ranges: 10 in/s, 1-315 Hz.
Max resolution in presentation: 0.002 in/s and 3 significant digits.
Threshold range: 0.02 9 in/s.
57B. DIN 4150-3 Anlage (US-units)
Erschütterungen im Bauwesen Teil 3: Einwirkungen auf bauliche
Anlage.
Level and frequency ranges: 1 in/s, 1-315 Hz.
Max resolution in presentation: 0.0002 in/s and 3 significant digits.
Threshold range: 0.002 0.9 in/s.
58A. PN-B-02170
Harmfulness assessments of vibrations transmitted by the foundation to
buildings.
Level and frequency ranges: 250 mm/s, 1-100 Hz.
Max resolution in presentation: 0.05 mm/s and 3 significant digits.
Threshold range: 0.4 220 mm/s.
58B. PN-B-02170
Harmfulness assessments of vibrations transmitted by the foundation to
buildings.
Level and frequency ranges: 25 mm/s, 1-100 Hz.
Max resolution in presentation: 0.005 mm/s and 3 significant digits.
Threshold range: 0.04 22 mm/s.
59. FTA VdB
Federal Transport Administration (USA)

Table of Contents