Level and frequency ranges: 50 - 118 dB (rel. 10
-6
in/s), RMS,
1-80 Hz. Filtered according to
ISO 2631-2, time constant 1 s.
Max resolution in presentation: 0.1 dB and 3 significant digits.
Threshold range: 60-115 dB. Transient file resolution:
0.002 in/s.
60A. NCh 3577
Metodología para evaluar las vibraciones producidas por voladuras sobre
infraestructuras.
Level and frequency ranges: 250 mm/s, 1-315 Hz.
Max resolution in presentation: 0.05 mm/s and 3 significant digits.
Threshold range: 0.4 220 mm/s.
60B. NCh 3577
Metodología para evaluar las vibraciones producidas por voladuras sobre
infraestructuras.
Level and frequency ranges: 25 mm/s, 1-315 Hz.
Max resolution in presentation: 0.005 mm/s and 3 significant digits.
Threshold range: 0.04 22 mm/s.