EasyManua.ls Logo

Silca Matrix Evo - Replacing Left-Hand Clamp Mobile Jaw; Replacing Right-Hand Mobile Clamp Jaw

Silca Matrix Evo
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Manual Matrix
Copyright Silca 2012 43
10.14.3 REPLACING LEFT-HAND CLAMP MOBILE JAW
1) Loosen the 2 screws (B3) and remove the stationary jaw (Ch.10.14.1).
2) Remove the knob (E) stop plate (S4) (Fig. 89).
3) Fully unscrew the knob (E).
4) Remove the mobile jaw and clean the clamp.
5) Fit the new jaw, screw in the knob and replace the plate (S4).
6) Fit the stationary jaw up against the left-hand side and align also from the front (Fig. 86).
7) Tighten the 2 screws (B3) without exerting pressure.
8) Check alignment (Ch. 10.13.1) and then fully tighten the 2 screws (B3).
Fig. 89 Fig. 90
10.14.4 REPLACING RIGHT-HAND MOBILE CLAMP JAW
1) Loosen the 2 screws (H3) and remove the stationary jaw (Ch.10.14.2).
2) Remove the knob (E1) stop plate (U4).
3) Fully unscrew the knob (E1).
4) Remove the mobile jaw and clean the clamp.
5) Fit the new jaw, screw in the knob and replace the plate (U4).
6) Fit the stationary jaw up against the right-hand side and align also from the front.
7) Tighten the 2 screws (H3) without exerting pressure.
8) Check alignment (Ch.10.13.2) and then fully tighten the 2 screws (H3).
Fig. 91 Fig. 92

Table of Contents

Related product manuals