Press F2 to view any manual adjustments set up by the PC program.
Press ENTER to continue, the display will show:
Press F1 to view the cutting method set up by Silca for the card in question.
Press F2 to enable or disable the electrical contact function for reading the key blank measurements.
1 - A red “X”
on the electrical contact icon means that it has been disabled.
2 - The symbol (*)
in the clamp field means that the key will be cut reading the key blank measurements by electrical
contact.
Note: some cutting cards do not include electrical contact. In such cases the software does not allow editing.
Note: when electrical contact is used it is advisable to set key blank measurements that are the same
as those of the key to be cut.