UNOCODE PRO Operating manual - English
40 Copyright Silca 2017
Press F3 to vary the setting for the value of the key blank measurements.
Note: when electrical contact is used it is advisable to set key blank measurements that are the same
as those of the key to be cut.
When the key blank has been fitted into the clamp on the cutter side and the safety shield is down, press START. The
cutting process starts.
The display will show:
When the first side has been cut, the display will show:
- Raise the safety shield and position the second side of the key to be cut.
- Lower the safety shield and press START, the display will show:
When the second side has been cut, the display will show:
Press STOP to finish the job.
Press ENTER to continue cutting other keys with the same cuts as
the key just finished.