Operating manual - English UNOCODE PRO
Copyright Silca 2017 49
Press ENTER, the display will show:
As the Z20 template is already on the reading clamp, just press START.
After an initial message of “Reading” the display will show (example):
Note: discrepancies in X of +/-0.03 mm from theoretical measurements can be considered normal.
Press STOP to confirm gauging without making mechanical regulations.
The X measurement read should be the same as the theoretical one (value=
400 in brackets).
If not, raise the safety shield and proceed as follows:
For an X value lower than 400, loosen the grub screw (P1) and use
a hex. wrench to tighten the screw (P2) (fig. 30).
ATTENTION: a quarter turn of the screw (P2) corresponds to a
movement of approximately 19 hundredths of a millimetre.
For an X value above 400, loosen the grub screw (P1) and use a
hex. wrench to loosen the screw (P2).
ATTENTION: quarter turn of the screw (P2) corresponds to a
movement of approximately 19 hundredths of a millimetre.
Fig. 30
P1
P2