EasyManua.ls Logo

Silca Unocode PRO - Page 54

Silca Unocode PRO
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNOCODE PRO Operating manual - English
50 Copyright Silca 2017
The Y measurement read should be the same as the theoretical one (value =
500 in brackets).
If not, proceed as follows:
For a Y value lower than 500, loosen the grub screw (P3) and use
a hex. wrench to tighten the screw (P4).
ATTENTION: a quarter turn of the screw (P4) corresponds to a
movement of approximately 19 hundredths of a millimetre.
For a Y value above 500, loosen the grub screw (P3) and use a hex.
wrench to loosen the screw (P4).
ATTENTION: a quarter turn of the screw (P4) corresponds to a
movement of approximately 19 hundredths of a millimetre.
Fig. 31
Tighten the grub screw (P3), lower the safety shield and press START; repeat the operation until the right values of X and
Y are set.
When the X and Y values are the same as the theoretical ones (in brackets or with errors between +/-
0.03mm) press STOP.
The display will show:
- Press STOP to repeat gauging.
- Press ENTER to confirm the gauging values read.
Press ENTER to confirm the operation and return to the menu
Calibrate jaw 3-V100-Standard.
Note: besides automatic gauging, the operator can make manual adjustments by entering the values
in the X and Y parameters.
ATTENTION: such adjustments (if necessary) are to be entered only after automatic gauging, if
applicable.
Adjustments can be made within a range of +30 and -30 hundredths of a mm.
- To adjust clamps and adapters the positive values of X will give the result shown.
- To adjust cutters, clamps and adapters the positive values of Y will give the result shown.
Press STOP to go back to the main menu.