DL100 Series Universal Low-Power Inverter
20 Function Parabeter Table
Chapter 5 Function Parameter Table
Parameter
Type
Function
Code
Name
Setting Range and
Description
Minimum
unit
Default
setting
Modification
limit
Basic running parameter group
F0.00
Frequency input
channel
0: Digital setting
1: External analog
quantity
2: External
communication
3: Panel
potentiometer
4: External terminal
selection
5: Combination
setting
1
3
F0.01
Frequency
digital setting
0.00Hz ~ upper
limit frequency
0.01
50.00
F0.02
Parameter write
protection
0: All parameters
can be modified
5: Only allow to
rewrite F0.01
parameter and this
parameter
9: Only allow to
modify this
parameter
Other values: all
parameters are
allowed to be
rewritten
1
0
F0.03
Upper limit
frequency
5.00~600.00
0.01
50.00
F0.04
Lower limit
frequency
0.00~[F0.03]
0.01
0.00
F0.05
Lower limit
frequency
operation mode
0~1
1
0