DL100 Series Universal Low-Power Inverter
Function Parabeter Table 21
F0.06
Run command
channel
And mode
selection
LED units
Run
command channel
selection
0: keyboard control
1: External terminal
control
2: Serial
communication port
LED ten digits
Run
command mode
selection
0: Two-line mode 1
1: Two-line mode 2
2: Three-line mode
Hundreds of LEDs:
reserved
LED thousands
Power-on self-start
0: Prohibition of
self-starting after
power-on
1: Power-on
self-start allowed
1
1000
F0.07
Running
direction setting
LED unitsReverse
running direction
0: invalid
1: Inverted direction
LED ten digits
Orientation lock
0: invalid
1: Reverse
prevention
2: Prevention of
forward rotation
1
0000
F0.08
Carrier
frequency
2.0~ 8.0 K
0.1
5.0
F0.09
Carrier
characteristics
0000~0001
1
0000
F0.10
Parameter
initialization
0~10
1
0
F0.11
Reserve
F0.12
Combination
setting selection
0~11
1
0
F0.13
Reserve
F0.14
acceleration
time
0.01 ~ 600.00 Sec
0.01
5.00
F0.15
deceleration
time
0.01 ~ 600.00 Sec
0.01
5.00
F0.16
Jog acceleration
time
0.01 ~ 600.00 Sec
0.01
5.00
F0.17
Jog deceleration
time
0.01 ~ 600.00 Sec
0.01
5.00
F0.18
Forward jog
frequency
0.00~[F0.03]
0.01
5.00
F0.19
Reverse jog
frequency
0.00~[F0.03]
0.01
5.00