DL100 Series Universal Low-Power Inverter
Detailed Description of Functions 53
Define PLC multi-speed running direction (binary setting).
PLC running direction setting.
LED units: Phase 1 direction selection
0Positive 1Reverse
LED ten digits: Phase 2 direction selection
0Positive 1Reverse
Hundreds of LEDs: Phase 3 direction selection
0Positive 1Reverse
LED Thousands: Phase 4 direction selection
0Positive 1Reverse
Including the acceleration or deceleration time from running to the current stage
frequency.
Define PLC multi-speed running direction (binary setting)
PLC running direction setting.
LED units: stage 5 direction selection
0Positive 1Reverse
LED ten digits: stage 6 direction selection
0Positive 1Reverse
Hundreds of LEDs: Stage 7 direction selection
0Positive 1Reverse
Thousands of LEDs:
When the programmable multi-speed running function is selected, this parameter is
used to set the programmable multi-speed running time. When the time is up, the
machine will stop automatically. When the operation is resumed, the stop command
should be given first, and then the start command should be given.
When this parameter is set to 0, the timer running stop function is invalid.
F5.15 PLC multi-stage running direction 1
Predetermined area
0000 ~1111H
F5.17 PLC running time Predetermined area
0 ~9999Min
F5.16 PLCMulti-stage running direction 2
Predetermined area
0000 ~0111
H