DL100 Series Universal Low-Power Inverter
Detailed Description of Functions 57
Ones place: 0:PID function closed 1:PID function enable
Ten place: reserved
Hundreds: reserved
Thousands: reserved
0:Positive characteristics 1:Inverse characteristics
This parameter can linearly correct the feedback signal.
0:Feed forward function is off
1~100:The feedforward action coefficient can increase the response speed
when the system is started.
This parameter group is the built-in PID controller parameter.
F7.07 Proportional gain Predetermined area
:
0.01~10.00
F7.08 Integration time Predetermined area
:
0.01~10.00 Sec
F7.02 PID value given Predetermined area
:
0.0~100.0%
F7.06 Reserve
F7.04 Feedback channel correction coefficient
Predetermined area
:
0.100~10.000
F7.03 Feedback channel feature selection
Predetermined area
:
0~1
F7.05 PID feedforward action coefficient
Predetermined area
:
00~100
F7.00 PID feature selection Predetermined area
:
0000 ~ 0011