RFC-1 Advanced Operation page 6.16
6.5.2 User-programmable Action Sequences
The RFC-1 can store up to 8 action sequences having up to 8 steps each. The available instructions are listed in the
text that follows along with a unique code that identifies each instruction. Select the instructions and program the
corresponding codes in the appropriate area of memory for the action sequence. The programming address table in
Appendix A provides a list of all memory address and their functions. Action sequences occupy addresses 0724-
0851 in the table.
This section of the programming address table for action sequence 1 is shown below. Notice that each step is
identified by two values that are listed as value 1 and value 2. These two values correspond to the column labeled
V1-V2 in the tables of available commands that follow.
- Programming -
Addr Description Section Default Current Alternate Use / Notes
0724 Action Sequence 1: step 1 – value 1 6.4.1 15 ____ _________________________
0725 Action Sequence 1: step 1 – value 2 6.4.1 15 ____ _________________________
0726 Action Sequence 1: step 2 – value 1 6.4.1 15 ____ _________________________
0727 Action Sequence 1: step 2 – value 2 6.4.1 15 ____ _________________________
0728 Action Sequence 1: step 3 – value 1 6.4.1 15 ____ _________________________
0729 Action Sequence 1: step 3 – value 2 6.4.1 15 ____ _________________________
0730 Action Sequence 1: step 4 – value 1 6.4.1 15 ____ _________________________
0731 Action Sequence 1: step 4 – value 2 6.4.1 15 ____ _________________________
0732 Action Sequence 1: step 5 – value 1 6.4.1 15 ____ _________________________
0733 Action Sequence 1: step 5 – value 2 6.4.1 15 ____ _________________________
0734 Action Sequence 1: step 6 – value 1 6.4.1 15 ____ _________________________
0735 Action Sequence 1: step 6 – value 2 6.4.1 15 ____ _________________________
0736 Action Sequence 1: step 7 – value 1 6.4.1 15 ____ _________________________
0737 Action Sequence 1: step 7 – value 2 6.4.1 15 ____ _________________________
0738 Action Sequence 1: step 8 – value 1 6.4.1 15 ____ _________________________
0739 Action Sequence 1: step 8 – value 2 6.4.1 15 ____ _________________________
Instructions in an action sequence are performed in order from step 1 to step 8. A step that is blankwill terminate
the action sequence. The instruction code for a blank instruction is 15-15. The factory setting for all user-
programmable action sequences is completely blank.

Table of Contents

Other manuals for Sine Systems RFC-1/B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sine Systems RFC-1/B and is the answer not in the manual?

Sine Systems RFC-1/B Specifications

General IconGeneral
BrandSine Systems
ModelRFC-1/B
CategoryRemote Control
LanguageEnglish

Related product manuals