RFC-1 Advanced Operation page 6.18
6.5.4 Action Sequence Delays
The RFC-1 pauses for about one-half second between the steps of an action sequence. This can be adjusted in an
individual action sequence by placing a delay instruction at the appropriate point(s) in the action sequence. Delay
instructions can be used in succession to create a longer delay. Select the appropriate delay instruction(s) from the
table below and program corresponding V1 in the action sequence as needed.
V1
V2
Delay Length
8
0
1 second
8
1
2 seconds
8
2
5 seconds
8
3
10 seconds
8
4
20 seconds
8
5
30 seconds
8
6
45 seconds
8
7
60 seconds
The default delay of one-half second between the steps of an action sequence can also be adjusted globally. This
setting changes the delay in between all instructions of all action sequences. Select an appropriate delay from the
table below and program V1 at address 1007 in the memory address table.
V1
Delay length
V1
Delay length
0
0.2 seconds
8
1.8 seconds
1
0.4 seconds (default setting)
9
2.0 seconds
2
0.6 seconds
10
2.2 seconds
3
0.8 seconds
11
2.4 seconds
4
1.0 seconds
12
2.6 seconds
5
1.2 seconds
13
2.8 seconds
6
1.4 seconds
14
3.0 seconds
7
1.6 seconds
15
3.2 seconds