RFC-1 Programming Examples page 7.4
7.4 Date/Time Trigger
In this example we will program Date/Time Trigger 1 to activate the action sequence that we programmed in the
previous segment. The action sequence is one that could be used to turn on a transmitter: activate the channel 00
on relay, pause 15 seconds, and then activate the channel 01 on relay. We will program the time trigger to activate
the action sequence every day at 6:00am.
1. Enter the advanced programming mode: 80
2. Enter the advanced programming security code: 4150
3. Enter the starting address from the address table for date/time trigger 1: 0632
4. Enter the number of the action sequence that should be triggered: 2
5. Press the # key to enter this value and increment to the next address in memory
6. Enter up to two digits for the month in which this trigger should function: 15 (every month)
7. Press the # key to write this value and increment to the next address in memory
8. Enter the first digit for the date in which this trigger should function: 15 (every day)
9. Press the # key to write this value and increment to the next address in memory
10. Enter the second digit for the date in which this trigger should function: 15 (every day)
11. Press the # key to write this value and increment to the next address in memory
12. Enter the first digit for the hour at which this trigger should function: 0
13. Press the # key to write this value and increment to the next address in memory
14. Enter the second digit for the hour at which this trigger should function: 6
15. Press the # key to write this value and increment to the next address in memory
16. Enter the first digit for the minute at which this trigger should function: 0
17. Press the # key to write this value and increment to the next address in memory
18. Enter the second digit for the minute at which this trigger should function: 0
19. Press the # key to write this value and increment to the next address in memory
20. Press the ❊ key to exit the programming mode
Section 6 describes the use of the value 15 in a date/time trigger to perform an event every month and/or every day.
The clock and calendar must be set before the time trigger can function. Issue the commands 70 and 71 in the
operating mode, not while in programming mode, and the RFC-1 will prompt for the time and date.