X coordinate of the min temperature
in the box
Y coordinate of the min temperature
in the box
Mark:
1. Thermal camera supports digital zoom, the temperature measuring box will zoom in and out according to
the digital zoom. Under digital zoom, the temperature measuring range should refer to the box responded
by the camera.
2. Read temperature of a box command is only available for ZT30 at this moment.
Read Temperature of the Full Screen
CMD_ID:0x14------Read Temperature of the Full Screen
0: Turn off temperature measuring
1: Measure the temperature once
2: Continuous temperature measuring
at 5 Hz
Max temperature of the full screen /
100 (two decimal places)
Min temperature of the full screen /
100 (two decimal places)
X coordinate of the max temperature
in the full screen
Y coordinate of the max temperature
in the full screen
X coordinate of the min temperature
in the full screen
Y coordinate of the min temperature
in the full screen
Mark: Read temperature of the full screen is only available for ZT30 at this moment.
Read Range from Laser Rangefinder
CMD_ID:0x15------Read Range from Laser Rangefinder
Range from Laser Rangefinder
low byte in the front, high byte in the
back
Minimum value is 50
Data unit is dm