A8 mini User Manual v1.5
35
2023 SIYI Technology Co., Ltd, All Rights Reserved
1
uint16_t
x
X coordinate of the point
2
uint16_t
y
Y coordinate of the point
3
uint8_t
get_temp_flag
0: Turn off temperature measuring
1: Measure the temperature once
2: Continuous temperature measuring
at 5 Hz
ACK data format
1
uint16_t
temp
Temperature of the point / 100 (two
decimal places)
2
uint16_t
x
X coordinate of the point
3
uint16_t
y
Y coordinate of the point
Mark: Read temperature of a point command is only available for ZT30 at this moment.
Read Temperature of a Box on Screen
CMD_ID:0x13------Read Temperature of a Box on Screen
Send data format
No.
Data Type
Data Name
Description
1
uint16_t
startx
X coordinate of the starting point of the
box
2
uint16_t
starty
Y coordinate of the starting point of the
box
3
uint16_t
endx
X coordinate of the ending point of the
box
4
uint16_t
endy
Y coordinate of the ending point of the
box
5
uint8_t
get_temp_flag
0: Turn off temperature measuring
1: Measure the temperature once
2: Continuous temperature measuring
at 5 Hz
ACK data format
1
uint16_t
startx
X coordinate of the starting point of
the box
2
uint16_t
starty
Y coordinate of the starting point of
the box
3
uint16_t
endx
X coordinate of the ending point of the
box
4
uint16_t
endy
Y coordinate of the ending point of the
box
5
uint16_t
temp_max
Max temperature in the box / 100 (two
decimal places)
6
uint16_t
temp_min
Min temperature in the box / 100 (two
decimal places)
7
uint16_t
temp_max_x
X coordinate of the max temperature
in the box
8
uint16_t
temp_max_y
Y coordinate of the max temperature
in the box