MK32E User Manual V1.1
75
2023 SIYI Technology, All Rights Reserved
4.6 Solutions to Disconnection
If SIYI system failed to establish datalink connection with GCS, please try to follow
the steps below to investigate possible reasons.
1. Confirm if the ground unit is bound with the air unit.
2. Confirm if the air unit is connected to the flight controller through telemetry
cable.
3. In “SIYI TX” app, go to Link Status” page to check connection status between
the ground unit and the air unit. When connection is normal, data “download” is
not 0. If it is “0”, please go back to check step 1 and 2.
4. Then go to “Datalink” page in SIYI TX app and check:
If “Connection” is correctly configured?
If “Flight Controller” is correctly configured?
If “Baud Rate” is correct when you use customized flight controller.
In your GCS, check if “Datalinkport is correctly configured.
5. If the flight controller is from Pixhawk family, please try to switch telemetry
cable connection between the TELEM 1 port and the TELEM 2 port.
Mark
If you have done investigation by following all steps above, but the reason is still not
located, please contact your dealer or SIYI immediately.