11
EN
11. Faults
- 45 -
951-171-016
Version 03
11. Troubleshooting
Fault table 1
Fault Possible cause Remedy
Pump does not run
- Power supply to the pump is interrupted
Check whether one of the indicated faults is present and rem-
edy it in the frame of responsibilities.
Faults outside of your own responsibility have to be reported
to your superior to initiate further measures.
- Superior machine is switched off
- Connection cable of pump is loose or defective
- External fuse is defective
- Pump motor is defective
- Internal cable break
Pump runs, but does not
supply lubricant or supplies
an insufficient amount of
lubricant.
Blockade, fault within the centralized lubrication system
Defective check valve
Defective pressure relief valve
Suction bore of pump element is clogged
Defective pump element
Too high lubricant consistency (at low temperatures)
In case of version F: Contaminated filter (mostly visible
from a "fluttering" display of the pressure gauge).
Check whether one of the indicated faults is present and rem-
edy it in the frame of responsibilities.
Faults outside of your own responsibility have to be reported
to your superior to initiate further measures.
Check and clean filter and replace, if necessary.
If the fault cannot be determined and remedied, please contact our Customer Service.