Fig. 2.3. Screen 2. Display and print settings.
Soft key Name Range/value Default value Description
1 DISPLAY v.split / h.split
/primary freq
v.split
Selection of screen layout (either vertical or horizontal split of the
total screen area, only primary transducer). Note: If only one of
the channels is being displayed, the other one can still be activated,
unless it is disabled by soft key LOCATION at screen 4. See “Fig.
2.5. Screen 4. Transducer details.” on page 17.
2 Not used.
3 DIGIT Small/large Small Selection of digital depth indication size.
4 PRINT O [not ready]
/on
O Start and stop of continuous printing. Note: If printer is not
connected, this button is “Dimmed” and can not be used.
5 SCREEN Print Screen hardcopy, can be used for documentation and trouble-
shooting.
6 SYSTEM On/o On Setting the sounder in standby mode, switching o the major
power consuming elements (transmitter, LCD screen etc.) The
sounder can be restarted by pressing any button. Note: The unit
is still energized!!! Do not perform any re-connections before
switching o the mains on the terminal PCB inside the cabinet.