EasyManua.ls Logo

Skipper GDS102 - System Reset and Configuration

Skipper GDS102
77 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 75 of 77
SKIPPER Electronics AS
Edition: 2017-06-12
GDS102 Operation and Installation Manual
First Page Last PagePrev Page Next Page
Chapter: 8. Service
Master Reset Procedure
After completed set-up procedure, you should always do a ‘’Master Reset’’:
Switch o the GDS102 using the internal toggle switch and wait a few seconds.
Then press down and keep pressed the soft key to the far left and far right (no. 1 and 6) in the upper row
on the GDS102 keyboard.
Turn “on” the GDS102, and keep the two soft keys pressed down until the screen shows the normal
picture. This may take as long as app. 30 seconds.
You should now normally hear 4 ‘’beeps’’.
You have now completed the “Master Reset” procedure.
Upgrading Software
New software versions are released from time to time. The GDS102 with Compact Flash (CF) can be
updated by performing the following software upgrade procedure.
1. If you have received a programmed compact ash, skip stage 2.
2. Newest software may be downloaded from the web http://www.skipper-service.no/skipdoc/skipdoc.php.
Under “software” you will nd your equipment type. Also copy the latest version of startup.exe into the
root folder.
Note: Standard Compact Flash reader is needed to be attached to the PC.
Note: It is possible to use the Compact Flash card, which is already installed in the display unit.
3. Switch “o” the mains of the display unit and insert Compact Flash card with the new software on it.
4. Press the “hidden” button inside the cabinet (mounted on the solder side of the keyboard). Keeping the
“hidden” button pressed, switch “on” the mains in the display unit and keep the button pressed while the
message “You may release the upgrade button” appears in the lower part of the screen. If a new setup.
exe is to be loaded, follow the on screen instructions.
5. Release the “hidden” button. After few diagnostic text messages, the list of available software versions
will appear in the lower part of the screen as in example below.
6. Note: If the bootloader does not nd any le with the software on the Compact Flash, the presently
installed version will start automatically. In this case, make sure, that the upgrade and setup le has been
copied correctly on the Compact Flash and repeat procedure.
1.13.01 1.12.10
External Active
KEY 1 KEY 2 KEY 3 KEY 4 KEY 5 KEY 6
7. Select a software version, which you would like to install. Normally, it is possible to chose one out
of two: the version, which is currently installed in the internal memory (indicated as Active) and the
upgrade version (indicated as External). The version name is displayed in the upper line of the text lines,
located just above the corresponding soft key. In the example above, soft key #1 should be pressed to
select the latest software version.
8. Conrm selection by pressing YES button (or go back to selection, pressing NO).
9. Press any button to start the upgraded software (or it will start automatically in 5 seconds).
10. Note: The le with a previous software version will be copied back to the Compact Flash card, so it
would be possible to re-install it in the similar manner, if desired.
Note: Always turn o the unit with the switch on the Combo Terminal board when removing/replacing the
CF disk