Section 6 – Procedures
Fold the guardrails
6.9-2 Fold the guardrail system down
(SJ4740)
1. Make sure the MEWP is on firm, level ground.
2. Make sure you fully lower the platform.
3. Push the emergency-stop button on the base
control console.
4. Turn the main power disconnect switch to the
off position.
WARNING
Fall hazard. Use the three points of contact
principle when you use the MEWP ladder to enter
or exit the platform. If you do not obey, there is a
risk of death or serious injury.
5. Use the MEWP ladder to enter the platform.
6. Close the gate.
7. Make sure you fully retract the extension
platform.
8. Loosen the wing screw from the top bracket of
the dual height control console.
9. Put the dual height control console down on
the platform floor.
10. Remove the lock-pins from the control console
mounting bracket
1
.
11. Remove the lock-pins from the railing clamp
2
. Remove the control cable from the railing
clamp.
1
2
12. Put the platform control console down on the
platform floor.
13. Remove the lock-pins from the extension
handrails.
Extension RailExtension Handrail
CAUTION
Install each lock-pin correctly with the detent
ball of each lock-pin fully through the bracket or
railing clamp. If you do not obey, there is a risk of
machine damage.
14. Pull the extension handrails, and install only the
lower lock-pin to lock the extension handrails.
15. Remove the lock-pins on the top rear gate.