SJ3220, SJ3226, SJ4720, SJ4726, SJ4732223198ABA
Section 5 – Procedures Skycoded Module
Fault Code Description
FINISHED!
This display occurs when all calibrations (dynamic, loaded up, loaded down, empty up,
empty down) have been completed, and the CALDATE has been entered.
Be sure to press <ESC> on the display module to exit calibration, before attempting to
use the machine.
GO UP MORE!
During calibration, the operator needs to close the UP or DOWN switch as required to lift
or lower the platform – if the switch is closed in the wrong direction, no fault occurs but the
machine does not move! This display claries the error.
GO DOWN MORE!
IGNORING
During static (loaded or empty) calibration, it may happen that a second measurement is taken very
close to the previous measurement (for example if the operator lets go the UP/DOWN switch – no
fault occurs, and this display indicates that the new measurement is being ignored.
PLEASE WAIT
During calibration, the Control Module CM1 sometimes delays while waiting for sensor values to
stabilize – this display indicates why nothing appears to be happening.