11 Troubleshooting
SMA Solar Technology AG
Operating manualSTPxx-US-50-BE-en-1180
Wait for higher irradiation.
If this message is displayed frequently in the morning, increase the voltage limit for starting grid
feed-in. Change the parameter Critical voltage to start feed-in.
If this message is displayed frequently with medium irradiation, ensure that the PV array is
correctly rated.
11.1.22 Event 4301
Event message:
Serial electric arc in string|s0| detected by AFCImodule
Explanation:
The inverter has detected an electric arc. The inverter stops feeding into the utility grid.
Corrective measures:
Disconnect the inverter from all voltage sources.
Check the PV modules as well as the cabling in the affected string for damage.
Ensure that the DC connection in the inverter is correct.
Repair or replace defective PV modules, DC cables or the DC connection in the inverter.
Reset the operation inhibition after an electric arc if necessary.
11.1.23 Event 6001-6468
Event message:
Self-diagnosis
Device fault
Explanation:
The cause must be determined by the Service.
Corrective measures:
Contact the Service.
11.1.24 Event 6501
Event message:
Self-diagnosis
Overtemperature