14 Technical Data
SMA Solar Technology AG
Operating manual STPxx-US-50-BE-en-11 95
Grid configurations 480/277 V wye connection
National standards and approvals,
as per 04/2023
UL62109-1, UL 1699B Ed. 1,
IEEE1547-2018, UL1741 SB, UL3741,
Canadian Electrical Code
®
CSA 22.2 No.
62109-1:16 / 62109-2:16, FCC Part 15
(Class A), PV Rapid Shutdown System
Equipment in accordance with UL1741:2021,
CA Rule 21, HECO Rule 14H, ISO-NE
14.2 DC Input
STP 20-US-50 STP 25-US-50 STP 30-US-50
Maximum power of PV
array
30000 Wp STC 37500 Wp STC 45000 Wp STC
Maximum input voltage 1000V 1000V 1000V
MPP voltage range 350Vto800V 430Vto800V 515Vto800V
Rated input voltage 685V 710V 710V
Minimum input voltage 150V 150V 150V
Initial input voltage 188V 188V 188V
Maximum usable input
current per input
24A 24A 24A
Maximum short-circuit
current per input
1)
37.5A 37.5A 37.5A
Maximum reverse cur-
rent into the PV mod-
ules
0A 0A 0A
Number of indepen-
dent MPP inputs
3 3 3
Strings per MPP input 2 2 2
Overvoltage category
in accordance with
UL62109-1
II II II
14.3 AC Output
STP 20-US-50 STP 25-US-50 STP 30-US-50
Rated power at 277V,
60Hz
20000W 25000W 30000W
1)
In accordance with UL62109-1: I
SCPV