EasyManua.ls Logo

SMART Board M600ix3 - Page 93

SMART Board M600ix3
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPENDIX B
REMOTELY MANAGING THE SYSTEM THROUGH AN RS-232 SERIAL INTERFACE
85 smarttech.com/kb/170910
Field
Possible Values
Description
current failurelog
l
Normal (NO)
l
Lamp Failed to
Strike (LS)
l
Lamp Failed (LF)
l
Lamp Hours
Reminder (Lh)
l
Lamp Voltage
Too High (LH)
l
System Fan 1 Fail
(F1)
l
System Fan 2 Fail
(F2)
l
System Fan 3 Fail
(F3)
l
Rear Blower Fan
Fail (F4)
l
Front Blower Fan
Fail (F5)
l
Colour Wheel Fail
(FC)
l
12 VDC Failure
(PS)
l
DDP Processor
Failure (FP)
l
DmD Failure (Fd)
l
Lamp Driver
failure (Fb)
l
Lamp Driver
Overheat (dH)
l
System Overheat
(OH)
Projector's error state. The modes are projector
dependent.
When get failurelog is used, the abbreviated
version of the error state (in parenthesis) is
retrieved.
When get error# is used, the full name of the
error is retrieved.
Current error# Provide the details of
the specific error. ā€œ#ā€
is the number
recorded in the log. It
ranges from 1 to 5. 1
indicates the most
recent error and 5
indicates the oldest
error.
The details include the failure reason, system
hours, lamp hours, sensor temperature and
lamp voltage.
Example:
error1=Rear Blower Fan Fail F4, syshrs:1000,
lamphrs=1000, temp=60,volt=120.
error2= System Overheat OH, syshrs:3000,
lamphrs=2900, temp=150,volt=120.

Table of Contents

Related product manuals