APPENDIX B
REMOTELY MANAGING THE SYSTEM THROUGH AN RS-232 SERIAL INTERFACE
85 smarttech.com/kb/170910
Field
Possible Values
Description
current failurelog
l
Normal (NO)
l
Lamp Failed to
Strike (LS)
l
Lamp Failed (LF)
l
Lamp Hours
Reminder (Lh)
l
Lamp Voltage
Too High (LH)
l
System Fan 1 Fail
(F1)
l
System Fan 2 Fail
(F2)
l
System Fan 3 Fail
(F3)
l
Rear Blower Fan
Fail (F4)
l
Front Blower Fan
Fail (F5)
l
Colour Wheel Fail
(FC)
l
12 VDC Failure
(PS)
l
DDP Processor
Failure (FP)
l
DmD Failure (Fd)
l
Lamp Driver
failure (Fb)
l
Lamp Driver
Overheat (dH)
l
System Overheat
(OH)
Projector's error state. The modes are projector
dependent.
When get failurelog is used, the abbreviated
version of the error state (in parenthesis) is
retrieved.
When get error# is used, the full name of the
error is retrieved.
Current error# Provide the details of
the specific error. ā#ā
is the number
recorded in the log. It
ranges from 1 to 5. 1
indicates the most
recent error and 5
indicates the oldest
error.
The details include the failure reason, system
hours, lamp hours, sensor temperature and
lamp voltage.
Example:
error1=Rear Blower Fan Fail F4, syshrs:1000,
lamphrs=1000, temp=60,volt=120.
error2= System Overheat OH, syshrs:3000,
lamphrs=2900, temp=150,volt=120.