-86-
No.PF※※-OMY0005
●Product individual parameters (continued)
AC_2ot
(Selection of output
type)
0: 1_P (Normal output)
1: 1_n (Reverse output)
P2(n2)_L
(Selection of output
set value)
Common for all ranges, units, and
criterion
P2(n2)_ft3
(Selection of output
set value)
Common for all ranges, units, and
criterion
0: 10 (L/pulse)
1: 100 (L/pulse)
OUT2 accumulated pulse converted
value setting
1000 L range
0:0.1 (L/pulse)
1: 1 (L/pulse)
2000 L range
0: 1 (Ft
3
/pulse)
1: 10 (Ft
3
/pulse)
2ot
(Selection of output
type)
0: 2_P (Normal output)
1: 2_n (Reverse output)
Setting of OUT2 normal and
reversed output
Dir
(Setting of the accumulated
flow direction)
FiL_FLoW
(Digital filter_flow rate)
0: 1.0 sec
1: 2.0 sec
2: 5.0 sec
FiL_PrES
(Digital filter_pressure)
10 ms increments (0 to 30 sec.)
FSC_PrES
(Fine adjustment of the
pressure span)
0.1% increments (-5 to 5%)
Refer to the Fig. Data for
the sub screen display
(Page 89)
0: Normal display
1: Reversed display
Zero cut-off setting 1.0% increments
Mes disp/hide_PrES
(Measurement display/
hide_pressure)
0: diSP (displayed)
1: HidE (hidden)
Measurement display/hide setting
Mes disp/hide_tEMP
(Measurement display/
hide_temperature)
0: diSP (displayed)
1: HidE (hidden)
Mes disp/hide_AC
(Measurement display/
hide_accumulated flow rate)
0: diSP (displayed)
1: HidE (hidden)
SAvE
(Accumulated flow value
hold setting)
0: oFF (Not held)
1: 2.0min
2: 5.0min
Display OFF
(Display OFF setting)
Pin
(Security code
Used/Not used)
PinCode
(Security code
setting)
Setting range
0x0000 to 0x03E7
(0 to 999)