4.3 MANUAL DOOR RELEASE PROCEDURE
If necessary, due to a malfunction or power blackout, the appliance can be opened manually by releasing the lock
using a screwdriver with stem Ø4mm; be gentle, taking care not to damage the device.
1. This procedure is only possible with the appliance in standby status, with no cycle running.
2. Warning: before opening the appliance manually, disconnect it from the electricity supply.
3. Insert a screwdriver or a rod 4 mm in diameter into the hole in the bottom of the centre of the front panel.
4. Push the pin upward until the lock is released.
fig. 5 Diagram showing how to release the lock by hand in any emergency.