Tethys D60 - Tethys T60 - Tethys T45
2 LIST OF MODELS
Model configuration chart; abbreviations used:
optional accessory, installable on the model.
feature not present and not installable on the model.
Models and Features
TABLE
DD - Powder detergent dispenser in inner door
P1 - Peristaltic detergent pump
P2 - Neutralising agent peristaltic pump
P3 - Optional peristaltic pump
P1 detergent dispensing monitoring
P2 acid neutralising agent dispensing monitoring
P3 pump dispensing monitoring
SL1 - P1 jerry can level monitoring
SL2 - P2 jerry can level monitoring
SL3 - P3 jerry can level monitoring
Runners in chamber for upper trolley
Standard Trolleys supplied
ELECTRICAL CONFIGURATION
Three different electrical setups are available for every 60cm model included in the table.
The names of the models have different suffixes to identify the power supply rating.
E.g.
- “Tethys D60-1” indicates single-phase model: “ 1N~ ”
- “Tethys D60-3” indicates three-phase model, 230V between phases, no neutral: “ 3~ ”
- “Tethys D60”. If the model does not have a suffix it will be three-phase, with neutral, 400V between
phases: “ 3N~ ”.
For the 45 cm model: Tethys T45, only the single-phase model is available: 230V ~ 50Hz electrical
connection with Schuko plug.
Contact your local dealer for advice about the model best suited to your needs.