2012/10/17 10:39:46 START PROGRAM: 7 Oper: 255
Cycle N.: 288
2012/10/17 10:40:17 START PHASE N.: 1
2012/10/17 10:41:12 Inflow Detergents P1:0.40%
2012/10/17 10:42:26 TL1: 22.7 TCL: 22.5
2012/10/17 10:42:26 Start heating Target temp. 93
2012/10/17 10:56:12 TL1: 94.1 TCL: 93.6
2012/10/17 10:57:36 TL1: 93.9 TCL: 93.4
2012/10/17 10:57:52 TL1: 94.1 TCL: 93.6
2012/10/17 10:59:43 TL1: 93.9 TCL: 93.4
2012/10/17 10:59:58 TL1: 94.1 TCL: 93.6
2012/10/17 11:01:53 TL1: 93.9 TCL: 93.4
2012/10/17 11:02:08 TL1: 94.1 TCL: 93.6
2012/10/17 11:04:12 TL1: 93.9 TCL: 93.4
2012/10/17 11:04:26 TL1: 94.1 TCL: 93.5
2012/10/17 11:05:53 Ao>=15983
2012/10/17 11:05:53 Start heating Target temp. 0
2012/10/17 11:05:53 TL1: 94.1 TCL: 93.6
2012/10/17 11:07:49 START PHASE N.: 2
2012/10/17 11:08:41 Inflow Detergents P2:0.20%
2012/10/17 11:09:34 TL1: 43.3 TCL: 42.3
2012/10/17 11:09:34 Start heating Target temp. 0
2012/10/17 11:11:34 TL1: 59.7 TCL: 59.2
2012/10/17 11:11:34 Start heating Target temp. 0
2012/10/17 11:11:34 TL1: 59.7 TCL: 59.2
2012/10/17 11:12:33 START PHASE N.: 3
2012/10/17 11:13:19 Inflow Detergents
2012/10/17 11:13:41 TL1: 36.9 TCL: 36.5
2012/10/17 11:13:41 Start heating Target temp. 0
2012/10/17 11:15:41 TL1: 49.9 TCL: 49.5
2012/10/17 11:15:41 Start heating Target temp. 0
2012/10/17 11:15:41 TL1: 49.9 TCL: 49.5
2012/10/17 11:16:41 START PHASE N.: 4
2012/10/17 11:17:26 Inflow Detergents
2012/10/17 11:17:49 TL1: 33.3 TCL: 32.9
2012/10/17 11:17:49 Start heating Target temp. 75
2012/10/17 11:25:47 TL1: 76.2 TCL: 75.7
2012/10/17 11:26:30 Start heating Target temp. 0
2012/10/17 11:26:30 TL1: 76.9 TCL: 76.5
2012/10/17 11:27:29 Start drying: TA_TARGET: 120 TA1: 73
2012/10/17 12:04:47 End drying: TA1: 89
2012/10/17 12:09:07 END PROGRAM: 7
================================================================================
fig. 28 Example of cycle data stored in the appliance’s memory.
The double line marks the
start and end of a program
Cons. number of CYCLE
Detergent dispensing
First phase, called “1
Phase Target temperature
A0 value reached
Second phase, called “2
Drying phase, with Target
temperature in Dryer duct
The two tank temperature probes
are called:
TL1 working probe
TCL control probe

Table of Contents