5. Reac-power (Not Required)
Description: Inverter will generate reactive power based on changing output power.
Note: This Setting is NOT required by Rule21 Standards.
This function is for maintenance personnel only, wrong operation
will prevent the inverter from reaching maximum power.
6. P-factor (Not Required)
Description: Inverter will change power factor based on changing output power.
Note: This Setting is NOT required by Rule21 Standards.
This function is for maintenance personnel only, wrong operation
will prevent the inverter from reaching maximum power.
YES=<ENT> NO=<ESC>
Power Factor: +1.00
Figure 6.30 Fixed-PF Figure 6.31 PF Range
7.VgWatt-UL (Not Required)
Description: Inverter will change the active output power based on voltage change.
Note: This Setting is NOT required by Rule21 Standards.
This function is for maintenance personnel only, wrong operation
will prevent the inverter from reaching maximum power.
6. Normal operation
57
NOTE
NOTE
NOTE

Table of Contents

Other manuals for SOLIS S5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SOLIS S5 Series and is the answer not in the manual?

SOLIS S5 Series Specifications

General IconGeneral
Number of MPPTs2
Output Voltage230 V
Frequency50/60 Hz
Max. AC Output Power5000W
Operating Temperature Range-25°C to +60°C
Rated AC Output Power2.5 kW / 3 kW / 3.6 kW / 4 kW / 5 kW / 6 kW
Max. AC Output Current21.7A
Cooling MethodNatural Convection
Humidity0~100 %
ModelS5 Series

Related product manuals