608 PHASE
CORRECTION
Select whether or not to carry out phase correction
control on the LTC generated by the timecode
generator.
OFF : No control.
ON: Carry out control.
Item number Item name Settings
607 U-BIT BINARY
GROUP FLAG
Select the user bits to be used in the time code
generated by the time code generator.
000 : Character set not specified.
001: 8-bit characters compliant with ISO 646 and
ISO 2022.
010: Undefined.
011: Undefined.
100: Undefined.
101: SMPTE 262M page/line multiplex system.
110: Undefined.
111: Undefined.
Menu items in the 600s, relating to the time code generator (continued)
606 TC OUTPUT SIGNAL
IN REGEN MODE
Select the signal output from the TIME CODE OUT
connector during normal (×1) speed playback in the
following two cases:
For tape playback when the INT/EXT switch in
the timecode section is set to INT and the
PRESET/REGEN switch is set to REGEN.
For preroll or postroll playback during automatic
editing with the tape.
TAPE : During tape playback, the playback
timecode signal is output without regeneration (in
this case the output video and the time code values
output from the TC OUT connector do not agree).
REGEN: The playback time code is output after
regeneration.