2-12
DXC-D30 (UC)
DXC-D30P (CE)
. Page 1 RESET
. Page 2 Shanding Correction
A SHAD
(YES )
B SHAD 123:
G SHAD 135:
R SHAD 118:
PAGE 2 (NEXT PREV )
EXIT MENU (YES )
. Page 3 Flare Adjustment
B FLARE 0:
G FLARE 0:
R FLARE 0:
PAGE 3 (NEXT PREV )
EXIT MENU (YES )
. Page 4 Pre Knee Setting
MPKNEE 1 67:
BPKNEE 128:
RPKNEE 128:
MPKNEE 4 255:
MPKNEE 3 164:
MPKNEE 2 116:
PAGE 4 (NEXT PREV )
EXIT MENU (YES )
The "RESET" mode is set to standard set
value except each board adjustment values
or differential adjustment values by each
unit. (Refer to table 1)
* In the NTSC, move the cursor to "DEST",
select UC, then move the cursor to
"RESET", and push UP
switch.
PAGE 1 (NEXT PREV )
RESET
(YES )
DEST : UC
EXIT MENU (YES )
(for NTSC)
PAGE 1 (NEXT PREV )
RESET
(YES )
EXIT MENU (YES )
(for PAL)
A SHAD (This is not functioned)
R SHAD / G SHAD / B SHAD
Shading correction of V
Standard (correction 0) = 128
Shoot the white portion of pattern box, adjust the UP
switch or
DOWN
switch so that the waveform is flat on the oscilloscope with
VD period.
VA-169 board Test point
CL101 (Rch)
CL201 (Gch)
CL301 (Bch)
R FLARE / G FLARE / B FLARE
Flare correction
(Not corrected at 0)
Regarding the adjustment, see the "SECTION 3 ALIGNMENT"
Standard value
MPKNEE1 Usual Master Pre Knee Point (D range 600%) :67
MPKNEE2 Master Pre Knee point at -3dB gain (D range 425%) :116
MPKNEE3 Master Pre Knee point at FM mode (D range 300%) :164
MPKNEE4 Master Pre Knee point at -3dB gain and FM mode
(D range 212%) :255
RPKNEE Rch Pre Knee Point fine Adjustment : 128
BPKNEE Rch Pre Knee Point fine Adjustment : 128