DXC-D30 (UC)
DXC-D30P (CE)
2-13
. Page 5 Component Level Adjustment
Y LVL 167:
S-UP LVL 144:
SYNC LVL 96:
B-Y LVL 154:
R-Y LVL 152:
PAGE 5 (NEXT PREV )
EXIT MENU (YES )
. Page 7 Chroma/VF Adjustment
B-Y CLP 110:
R-Y CLP 107:
Y CLP 143:
PAGE 6 (NEXT PREV )
EXIT MENU (YES )
R-Y CAL 108:
VF BLKG 105:
VF SYNC 142:
B-Y BST 77:
B-Y CAL 103:
R-Y BST 0:
PAGE 7 (NEXT PREV )
EXIT MENU (YES )
. Page 8 SC adjustment
SC–H 1104:
SC FRE 2278:
PAGE 8 (NEXT PREV )
EXIT MENU (YES )
. Page 6 CLP Level Adjustment
. Set the camera main unit to color-bar mode and perform the following
adjustments. Use an extension (EX) board to ES-12 board.
Measurement Point
R-Y CAL Carrier balance adjustment of R-Y VBS OUT
R-Y BST Burst level adjustment of R-Y direction VBS OUT
B-Y CAL Carrier balance adjustment of B-Y VBS OUT
B-Y BST Burst level adjustment of B-Y direction VBS OUT
VF SYNC Sync level adjustment of VF video EX board :TP-82
VF BLKG BLKG level adjustment of VF video EX board :TP-82
Measurement Point
SC FREQ SC frequency adjustment ES board :TP-501
SC-H SC-H adjustment VBS OUT
. Set the camera main unit to color-bar mode and perform the following
adjustments. Use an extension (EX) board to IF-532 board.
Measurement Point
Y CLP CLP Level adjustment of Y EX board :TP-61
R-Y CLP CLP Level adjustment of R-Y EX board :TP-60
B-Y CLP CLP Level adjustment of B-Y EX board :TP-62
. Set the camera main unit to color-bar mode and perform the following
adjustments. Use an extension (EX) board to IF-532 board.
Measurement Point
Y LVL Level adjustment of Y EX board :TP-61
R-Y LVL Level adjustment of R-Y EX board :TP-60
B-Y LVL Level adjustment of B-Y EX board :TP-62
SYNC LVL Level adjustment of SYNC EX board :TP-61
S-UP LVL Level adjustment of SETUP EX board :TP-61