[TC/UB] SET Menu
TC/UB SET
Menu items Subitems and setting values Contents
Timecode
Setting the
timecode
Mode
Preset / Regen / Ext Regen /
Clock
Set the timecode mode.
[Preset]: To start the timecode from the specified value
[Regen] (regeneration): To continue the timecode during
recording only. When you insert another SxS memory
card, the recorder starts next recording so that the timecode
continues from the last recorded timecode on the card.
[ExtRegen] (external regeneration): To synchronize to the
timecode superimposed on the internal input signal.
[Clock]: To use the current clock time as the timecode
Run
Rec Run / Free Run
Set the running mode when the timecode mode is set to
[Preset].
[Rec Run]: To advance the timecode during recording only.
The continuity of the timecode is maintained between clips
in the sequence of recording as long as the SxS memory
card is not changed. If you remove the memory card and
record on another card, the timecode will not continue
when you return the first card to the slot again.
[Free Run]: The timecode keeps advancing regardless of the
state of recording to the SxS memory card. Always select
[Free Run] when [Mode] is set to [ExtRegen].
Setting Set the timecode to a desired value.
Reset
Execute / Cancel
Select [Execute] to reset the timecode to ā€œ00:00:00:00.ā€
Users Bit
Setting the user
bits
Mode
Fix / Date
Set the user bit mode.
[Fix]: To use a desired fixed value as the user bits
[Date]: To use the current date
Setting Set the user bits to a desired value.