Changing Basic Settings
23
Recording
UDF/SD mode
exFAT/SD mode
FAT/SD mode
Setting the Timecode
Specify the timecode to be recorded with
[Timecode] and [TC Format] in the [TC/UB SET]
menu (page 53). The following methods are
available for recording the timecode.
Preset mode (Preset)
Records an internally generated timecode with a
preset initial value. You can select one of the
following run modes.
Free Run: Timecode is always running.
Rec Run: Timecode runs only when recording.
Regeneration mode (Regen)
Records an internally generated timecode that
continues from the timecode of the last recorded
clip.
External regeneration mode (ExtRegen)
Records an internally generated timecode that is
synchronized to the timecode superimposed on an
external input signal. If a timecode is not
superimposed on an input SDI signal, the value of
the internal timecode generator is used as the
initial value.
Setting the Users Bit
You can add a hexadecimal number of 8 digits for
pictures as the user bits.
The user bits can also be set to the current date.
Use [Users Bit] (page 53) in the [TC/UB SET]
menu.
Displaying the Time Data
Pressing the DISPLAY button displays the time
data on the screen (page 9). The indication is
switched among the timecode, user bits, and
recording duration by pressing the DURATION/
TC/U-BIT button (page 6).
The output mode of the video signal output on the
SDI OUT 1 connector can be selected when
editing while simultaneously outputting video.
The setting is made in [SDI OUT1 Mode Select]
of the [VIDEO SET] menu. The image on the
LCD monitor is output from the SDI OUT 2,
HDMI, VIDEO OUT, and i.LINK connectors.
[Normal] mode: The same video as that
displayed on the LCD monitor is output.
[Through] mode: The SDI IN input signal is
always output, regardless of the operating state.
[Auto] mode: The playback video is output
during playback operations on the recorder
(PLAY/PAUSE, F FWD, F REV). In all other
cases, the SDI IN input signal is output.
In Auto mode, [SDI/HDMI/Video Out Super]
(page 51) in the [VIDEO SET] menu is set to
[Off], and no character information is output.
[Rec Format] setting Input signal format
DVCAM 50i 576/50i
IMX50 50i 576/50i
[Rec Format] setting Input signal format
DVCAM 50i 576/50i
IMX50 50i 576/50i
[Rec Format] setting Input signal format
DVCAM 50i 576/50i
Time Data
Display Contents
TCG **:**:**:** Timecode
TCR **:**:**:** Timecode superimposed on the
input signal
CLK **:**:**:** Timecode (Clock mode)
UBG ** ** ** ** User bits
UGR ** ** ** ** User bits superimposed on the
input signal
DUR **:**:** Duration from the beginning of
recording