KGE/EN (1711) 6.5 Maintenance 29
KGE
6 Maintenance
! Flawed maintenance will result in shorter lifespan, possible break down and
in any event loss of warranty.
6.1 Precautionary measures
Insufficient, wrong and/or irregular maintenance can lead to malfunctions
in the pump, high repair costs and long-term inoperability. Therefore, you
should carefully follow the guidelines given in this chapter during
maintenance operations on the pump. Non-compliance with prescriptions
or warnings may be dangerous for the user and/or seriously damage the
pump / pump group.
All work should be carried out by suitably trained personnel.
Pump and piping may contain high pressure liquids, high temperature
liquids or/and hazardous chemical fluids even when the unit has been shut
down. Before dismantling, always allow the pump to cool (20 °C) and allow it to drain
completely.
Ensure that the working area is clean, because certain parts such as the mechanical
shaft seals are extremely vulnerable and others have very close tolerances.
Installation, operation and maintenance has to be done by qualified and well prepared
personnel.
! In case of storage :
The pump must be operated briefly once a week or alternatively one manually makes a
full revolution of the pump shaft.
This ensures a proper circulation of the protective oil.
6.2 Daily
Keep both the surface of the pump and the surroundings as clean as possible. This
simplifies inspection (attached markings remain visible).
Never spray the hot parts of a pump with water, as certain components may
crack due to the sudden cooling and the fluid being pumped may spray in to
the environment.
6.3 Periodic inspection
The pump should run smoothly and free from noise or vibration
Shaft alignment and levelness of the base plate
Gasketed seals at pump casing and seal cover and suction / discharge connections
should be inspected for leaks.

Table of Contents