T15h Tag Deployment & User Guide
28
a. Temperature Units:
Select the temperature unit (Celsius/Fahrenheit).
b. Temperature Alarm Settings:
Local Alarm: The Local Alarm includes 3 components; Buzzer,
Alert LED and the on-screen Bell icon. These are all triggered if
the configured temperature values are out of range. By default
the (in UD mode)
toggling the button.
Note: The buzzer will continue to sound unless muted on the tag
itself.
Min & Max Temperature Thresholds: Set the minimum and
maximum temperature threshold values. The tag s Local Alarm
will be triggered when a value is out of its configured range.
Alarm Delay Period: Select
must be out of a configured range before an alarm is triggered.
For example; if the alarm delay period is set to 5 minutes and the
the alarm will only be
triggered if its value does not normalize within the set time of 5
minutes.
Note: The tag will immediately move out of alarm mode when
the temperature is back within the configured limits.