Environmental Specifications
− Operating Temperature Range: 0°C to 50°C (32°F to 122°F)
− Tag Storage Temperature Range: -20°C to 60°C (-4°F to 140°F)
− Humidity: 0% to 95% RH non-condensing
− Ingress Protection Rating: IP-52
Monitoring Temperature & Humidity Ranges
− Temperature Measurement Range: 0°C to +50°C (32°F to +122°F)
− Accuracy: +/-0.5° C (+/-1° F)
− Humidity Measurement Range: 5% to 95% RH
Tag Memory
− 64 Mbit Flash memory
− Able to store up to 128.000 readings
Physical and Mechanical
− Dimensions LWH: 114 x 77 x 20.3mm (4.4 x 3 X 0.8inch)
− Weight: 150g (5.3oz) with batteries
Connectors
− 1 x USB-C connector
Electrical
− Battery: 2 x 1.5V Alkaline AA replaceable batteries
− External Power (USB-C Interface): 5V/1A Adapter (Optional)
ATTENTION: The AC/DC adaptor must be safety-approved according
to IEC/EN/UL 60950-1 with a rated voltage of 5Vdc and rated current
up to 3A maximum.
Display
− E-ink
Audio and Visual Indications
− Audio: Buzzer- 85dBA@10cm
− LEDs: 3 dual-color LEDs
Radio
− Transmission power: up to +19dBm (~81mW)
− Patented clear channel sensing avoids interference with wireless
networks