3.6.2. 2D Code Command Setting Font
QR code setting fonts (QR_CNTL)
QR_CNTL Fonts Function Output Code
0 Use for Parameter \x00
1 Use for Parameter \x01
2 Use for Parameter \x02
3 Use for Parameter \x03
4 Use for Parameter \x04
5 Use for Parameter \x05
6 Use for Parameter \x06
7 Use for Parameter \x07
8 Use for Parameter \x08
9 Use for Parameter \x09
M Set model of QR code \x1b\x1dyS0
M1 Set model of QR code: Model 1 \x1b\x1dyS0\x01
M2 Set model of QR code: Model 2 \x1b\x1dyS0\x02
E Set up correct errors level \x1b\x1dyS1
* El (E0)
Correct errors level L
(correction rate: 7%)
\x1b\x1dyS1\x00
*
Em (E1)
Correct errors level M
(correction rate: 15%)
\x1b\x1dyS1\x01
* Eq (E2)
Correct errors level Q
(correction rate: 25%)
\x1b\x1dyS1\x02
* Eh (E3)
Correct errors level H
(correction rate: 30%)
\x1b\x1dyS1\x03
S1~S8 Set module size (unit: dot) \x1b\x1dyS2 (\x01~08)
A0
QR code data setting
(automatic data analysis)
\x1b\x1dyD1\x00
B
QR code data setting
(manual data analysis)
\x1b\x1dyD2
P Print QR code data \x1b\x1dyP
*) The correct errors level can also be set using the correction rate enclosed by parentheses ().