10
NOTE: This system incorporates a 12 volt burner and blower assembly and burns #2 diesel
fuel. A 12 volt battery and charging circuit supply power to the burner, blower motor, and ther-
mostat. The charging circuit may consist of an engine driven alternator mounted on the unit,
or a hook-up to the tow vehicles charging system. The thermostat will automatically control
the burners to maintain the desired temperature. The temperature of the material is shown on
LCD digital displays.
Igniting Burner
1. Check fuel tank for proper fuel type and quantity.
2. Set thermostat to the product manufacturers recommended level.
3. Turn ON burner power switch and the burner will ignite.
4. Operate battery charging device.
To Shut Off Burner
1. Set thermostat to the lowest setting.
2. Turn OFF burner power switch.
CAUTION: The burner requires a minimum of 12 volts for proper operation. Poor combustion
with excessive smoke and lack of heat or burner malfunction will result with lower voltage. As-
sure the battery is fully charged and the charging circuit is operating properly for maximum
performance.
OPERATIONS Diesel Burner w/ Thermostat