© STid – MU_ULTRYS_V3.0.1_EN
Adjust the antenna power (10% to 100%) to adjust the reading distance.
Adjust the reading time in steps of 1 second (max 30s). This parameter is taken into account only
if in the Input type selection, the reading mode is set to "Triggering of reading on the event".
The EPC filter is not available in Secure Mode.
Enter the value for EPC Mask, max 62 hexadecimal bytes.
Adjust the value for offset EPC mask in bytes (0 to 61 bytes).
It depends on the EPC Mask length.
Filter inversion not selected: only tags with an EPC value corresponding to the EPC mask value
will be provided to the user.
Filter inversion selected: only tags with an EPC value different from the EPC mask value will be
provided to the user.
RSSI (Received Signal Strength Indication) is a measure of the power in reception of the tag
response. The value returned by the reader is proportional to the amplitude of the reception
signal.
Adjust the RSSI value (-110dBm to 0dBm). 0dBm deactivates the RSSI filter.
Filter inversion not selected: only tags with an RSSI greater than or equal to the specified value
will be provided to the user.
Filter inversion selected: only tags with an RSSI smaller or equal to the specified value will be
provided to the user.
Ex: RSSI filter= -49dBm + Reversal not selected
A tag that will have a RSSI value of -20dBm will be sent back,
A tag that will have a RSSI value of -60dBm will not be sent back.