OPERATION
6.3.2 Operating Hydro-Fix
WARNING
Risk of injury and material damage due to soiled hydraulic couplings!
Hydro-Fix couplings that are not cleaned on a regular basis can result in plug parts not being correctly
connected or parts of the Hydro-Fix being damaged when attempting to couple them. This can cause
malfunctions of the hydraulic system. All functions of the hydraulic system can result in uncontrolled
movements of the implement or of the front loader, and cause severe injuries.
Clean the Hydro-Fix before coupling.
Always close the cover of the lower part of the Hydro-Fix to prevent contamination.
Coupling the hydraulic lines:
(1) Open the cover on the lower part
(see 3.7.2 Multiple coupling Hydro-Fix).
(2) Wipe the coupling surfaces with a cloth.
Do not wipe dust into any nearby plug
connectors.
(3) Press the lock button and push the lever
upwards.
(4) Remove the protective cap on the upper
part.
(5) Remove the upper part from the holder on
the front loader.
(6) Insert the upper part into the bottom part
using the guide pins.
(7) Push the lever down.
The guide presses the upper part onto the
lower part by means of the pins. The lock
button is pushed out.
The hydraulic lines are coupled.
Uncoupling the hydraulic lines:
(1) Press the lock button and push the lever
upwards.
(2) Pull out the upper part.
(3) Put on the protective cap.
(4) Hook the upper part onto the appropriate
mounting on the front loader.
(5) Close the cover on the lower part.
(6) Push the lever down.
The hydraulic lines are uncoupled.
Fig. 65 Hydro-Fix
Legend
1 Hydro-Fix upper part
2 Guide pins
3Pin
4Cover
5 Guide
6Lever
7 Lock button